Multifunctional Gate Box MGB 4 Results Print this Page
Image MFG. Part # Description MFG. On Hand Price From
MGB-AP Auxiliary release Connection using cable entry, M20 x 1.5 or plug connector Plug connector connection, either HC26, RC18 or M12 12-pin Operation of guard locking via IMP as control input on PLC (only 3 mA) Monitoring outputs OD = ON when door is closed. OT = Bolt tongue inserted in the evaluation module (in case of guard locking devices ready for operation of the solenoid. In case of interlocking devices corresponds to safety outputs) OL = Guard locking solenoid locked in position (in case of guard locking devices corresponds to safety outputs) OI = Diagnostics, there is a fault More information Economical wiring according to standards The family MGB-AP is particularly suitable for the protection of individual safety doors. If series connection is not necessary, wiring can then be saved. This version has different timing to the AR version. Interlocking or guard locking? Functions of the versions MGB-L0, MGB-L1 and MGB-L2 compared Interlocking devices (MGB-L0, without guard locking) Together with a handle module, the interlocking module makes it possible to interlock the control of movable safety guards. The combination also serves as a mechanical door stop at the same time. The following switch-on condition applies to the safety outputs OA and OB: Safety guard closed (but can be opened at any time) Bolt tongue inserted in the interlocking module The interlocking module detects the position of the safety guard and the position of the bolt tongue. The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle. Guard locking devices (MGB-L1 and MGB-L2) Together with a handle module, the locking module makes it possible to lock movable safety guards. The combination also serves as a mechanical door stop at the same time. The following switch-on condition applies to the safety outputs OA and OB: Safety guard closed Bolt tongue inserted in the locking module Locking arm in locking position (the door cannot be opened) The EUCHNER -
MGB-AR Auxiliary release Connection using cable entry, M12 x 1.5 or plug connector Plug connector connection, either RC18 or M12 12-pin Operation of guard locking via IMP as control input on PLC (only 3 mA) Monitoring outputs OD = ON when the door is closed. OT = Bolt tongue inserted in the evaluation module (in case of guard locking devices ready for operation of the solenoid. In case of interlocking devices corresponds to safety outputs) OL = Guard locking solenoid locked in position (in case of guard locking devices corresponds to safety outputs) OI = Diagnostics, there is a fault More information Economical wiring according to standards All devices in the family AR can be wired directly in series in a so-called AR series connection without reducing safety or the PL. As a consequence evaluation units are saved. AR devices are also available in the EUCHNER series CES and CET. Interlocking or guard locking? Functions of the versions MGB-L0, MGB-L1 and MGB-L2 compared Interlocking devices (MGB-L0, without guard locking) Together with a handle module, the interlocking module makes it possible to interlock the control of movable safety guards. The combination also serves as a mechanical door stop at the same time. The following switch-on condition applies to the safety outputs OA and OB: Safety guard closed (but can be opened at any time) Bolt tongue inserted in the interlocking module The interlocking module detects the position of the safety guard and the position of the bolt tongue. The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle. Guard locking devices (MGB-L1 and MGB-L2) Together with a handle module, the locking module makes it possible to lock movable safety guards. The combination also serves as a mechanical door stop at the same time. The following switch-on condition applies to the safety outputs OA and OB: Safety guard closed Bolt tongue inserted in the locking module Locking arm in locking position EUCHNER -
MGB-PN PLe/Category 4 for all safety functions Handle, bolt and guard locking in one Integrated PROFINET RT switch Profisafe integrated More information Seamless integration by means of bus connection In the PROFINET version we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary PROFINET input and output bytes required. Comprehensive diagnostic information in the form of PROFINET messages makes troubleshooting quick and specific. Due the typical ease with which parameters can be set in PROFINET, even the replacement of the system in case of service is a simple matter and can be undertaken in a few minutes. Interlocking or guard locking? Functions of the versions MGB-L0, MGB-L1 and MGB-L2 compared Interlocking devices (MGB-L0, without guard locking) Together with a handle module, the interlocking module makes it possible to interlock the control of movable safety guards. The combination also serves as a mechanical door stop at the same time. The following switch-on condition applies to the safety outputs OA and OB: Safety guard closed (but can be opened at any time) Bolt tongue inserted in the interlocking module The interlocking module detects the position of the safety guard and the position of the bolt tongue. The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle. Guard locking devices (MGB-L1 and MGB-L2) Together with a handle module, the locking module makes it possible to lock movable safety guards. The combination also serves as a mechanical door stop at the same time. The following switch-on condition applies to the safety outputs OA and OB: Safety guard closed Bolt tongue inserted in the locking module Locking arm in locking position (the door cannot be opened) The locking module detects the position of the safety guard and the position of the bolt tongue. The position of the guard locking is EUCHNER -
MGB-Ethernet-IP Maximum safety, category 4/PL e Safety system with guard locking, handle and bolt Integrated Ethernet/IPª switch CIP Safety protocol More information Seamless integration by means of Ethernet/IPª The MGB is a safety system with guard locking and guard lock monitoring for the protection of safety doors on machines and installations. In the Ethernet/IPªª version, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary CIP Safety input and output bytes required. Whether interlocking, guard locking, escape release or other functions such as buttons for start/stop, emergency stop, selector switch, etc. Ð the MGB meets all requirements for safety-related applications and can be equipped on a customer-specific basis. Comprehensive diagnostic information in the form of Ethernet/IPª messages provides a fast and detailed overview of the device status. Due to the ease with which parameters can be set, even the replacement of the system in case of service is a simple matter and can be performed in a few minutes. Guard locking devices (MGB-L1 and MGB-L2) Together with a handle module, the locking module makes it possible to lock movable safety guards. The combination also serves as a mechanical door stop at the same time. The following switch-on condition applies to the safety outputs OA and OB: Safety guard closed Bolt tongue inserted in the locking module Locking arm in locking position (the door cannot be opened) The locking module detects the position of the safety guard and the position of the bolt tongue. The position of the guard locking is also monitored. The bolt tongue in the handle module is moved into and out of the locking module by actuating the door handle. When the bolt tongue is fully inserted in the locking module, the locking arm locks the bolt tongue in this position. Depending on the version, this locking is by spring force or solenoid force. Ver EUCHNER -
For any item showing no stock on hand, most likely we can get for YOU. Just give us a call or send us online RFQ.
© 2017 Cplus Electronics, Inc. All Rights Reserved. | Powered by Rootways
TOP